Step 1

Use remote pulley to close compression needle to a firm stop by turning it clockwise. This is now in the lockout position.

img/help/page2999-9SX6/IMG_0697.2 copy.jpg
img/help/page2999-9SX6/IMG_0698.2 copy.jpg
img/help/page2999-9SX6/IMG_0710 copy-m.jpg

Step 2

Sub-assemble the Top Cap interface parts. Place the Torsion Spring, aligning the vertical leg of Torsion Spring, into the hole in the bottom of the Cable Remote Pulley. Align the Pulley Set screw facing the dot opposite to the arrow. Engage the horizontal tang of the torsion spring with the Cable Housing.

img/help/page2999-9SX6/IMG_0710 copy.jpg
img/help/page2999-9SX6/IMG_0713 copy.jpg
img/help/page2999-9SX6/IMG_0712 copy.jpg
img/help/page2999-9SX6/IMG_0714 copy.jpg
img/help/page2999-9SX6/IMG_0717 copy-m.jpg

Step 3

Install sub-assy onto Damper with arrow facing desired direction for cable routing. While holding Housing and Pulley assembly in place, install the Pulley Fastener through the top of the Remote Pulley and thread 4-5 turns clockwise into the Remote Adjuster Rod.

img/help/page2999-9SX6/IMG_0717 copy.jpg
img/help/page2999-9SX6/IMG_0718 copy.jpg
img/help/page2999-9SX6/IMG_0723 copy-m.jpg

Step 4

Rotate only Cable Housing 270° CW (Clockwise) to preload Torsion Spring. Check cable direction. When locked out, check that Pulley Set Screw is alingned to Mark. Torque screw to 4in/lbs while holding Pulley. Pulley must return freely after unlock.

img/help/page2999-9SX6/IMG_0723 copy.jpg
img/help/page2999-9SX6/IMG_0722 copy.jpg
img/help/page2999-9SX6/IMG_0721 copy.jpg