SERVICE PROCEDURES
2019-2023 LIVE Valve MTB Shock Rebuild
Required Parts
- 803-00-142 Kit: Rebuild, FLOAT Line Air Sleeve, Special Q-Ring
- 803-04-012 Service Kit: LIVE Shocks Rebuild kit, Gen 2
Required Tools
- 398-00-280 Tooling: Eyelet Torque Tool
- 398-00-806 Tooling: LIVE Valve Solenoid Housing Puller
- 398-00-820 Tooling: LIVE Solenoid Switcher
- 398-00-951 Tooling: Torque Fixture, 54mm Trunnion Eyelet, Tall
- 803-00-566 Kit: Bike IFP Depth Setting Tool Set
- 803-00-805 Kit: Shaft Clamps, Shocks, CTD 9mm, 3/8in, 1/2in, 5/8in
- 803-01-360 Kit: Tooling: LIVE Valve Clamp, Solenoid Housing, 8mm Shaft, Pressure Tube
- 803-01-369 Kit: Tooling: Glide Band Sizer, Live Valve, Fork/Shock
- 803-01-370 Kit: Fill Machine Adapter, Live Valve Fork/Shock
Supplies Needed
WARNING: Always wear safety glasses and protective gloves during service to prevent potential injury. Failure to wear protective equipment during service may lead to SERIOUS INJURY OR DEATH.
NOTE: The LIVE Valve damper is extremely sensitive to contamination from debris. It is critical that all work be performed in a clean environment using only new lint-free paper towels and Isopropyl alcohol to clean.
Disassembly
Never pull on the wires connecting the Solenoid to the cable connector as damage may occur. Any damage to the Solenoid, Solenoid wires, or cable connector will require replacement of the Solenoid assembly.
Step 6
Remove the white Delrin ball from the Compression Cartridge Housing bleed port. It can be helpful to heat your metal pick before removing the Delrin ball. Unthread and remove the bleed screw counter-clockwise with a 5/64" hex wrench. Remove the 0.125" ball bearing from the bleed port with a magnet.
Step 8
Thread a 5/16-24 threaded rod or bolt into the Reservoir End Cap then pull up to remove it. If you do not have a 5/16-24 threaded rod or bolt, pull up on the Reservoir End Cap with pliers on the flats of the raised portion of the end cap. Do not use pliers on the external threads of the end cap. Replace the o-ring on the end cap with a new greased one from the kit.
Step 16
Remove the white Delrin ball from the screw connecting the Reservoir Assembly to the Eyelet Assembly. Unthread and remove the bolt holding the Reservoir Assembly to the Eyelet Assembly by turning it counter-clockwise with a 4mm hex wrench. Lift the Reservoir Assembly off of the Eyelet Assembly making sure to keep track of the small Dowel Pin between the two assemblies.
Step 23
Non-Trunnion Eyelets: Remove the set screw from the rear of the Eyelet by turning it counter-clockwise with a 2mm hex wrench. Remove the detent spring and ball bearing.
Trunnion Eyelets: The rebound detent spring and ball bearing will be disassembled as you remove the Rebound Metering Rod in a later step.
Step 25
For Trunnion Eyelets: Install the Trunnion Eyelet Tool (PN: 398-00-099) onto the Eyelet Assembly making sure to thread the bolts fully clockwise into the Trunnion Eyelet holes.
For All Eyelets: Heat the shaft for 4-5 seconds with a propane torch to break down the red Loctite bond. Unthread the Eyelet Assembly counter-clockwise to remove it from the shaft.
Step 26
Remove the Rebound Metering Rod from the Eyelet by pulling it out. Use the hex feature on the end of the Rebound Metering Rod to unthread the Rebound Adjuster Insert counter-clockwise from within the shaft. Clean any Loctite residue from the shaft threads within the Eyelet. Replace the shaft o-ring within the Eyelet with a new greased one from the kit.
LIVE Compression Housing Rebuild
Step 9
Remove the two glide rings and two o-rings from the Compression Cartridge Housing. Replace the two o-rings on the Compression Cartridge Housing with new ones from the kit. Coat the o-rings with FOX 5wt Teflon Infused oil. Replace the two glide rings with new ones from the kit. Make sure that the o-rings do not get pinched by the glide rings during installation.
Step 15
Reinstall the Solenoid Retainer Plate with its notch aligned with the two wires exiting the Solenoid. Reinstall the wire retaining ring making sure that it is fully seated in the groove. Orient the retaining ring so the gap in the ring is opposite the gap in the plate that the wires go through.
General Reassembly
Step 2
For non-Trunnion Eyelets: Insert the red Rebound Knob into its position in the slot of the Eyelet. Insert the Rebound Metering Rod into the Eyelet through the hole for the Shaft with the o-ring end first. Engage the hex feature of the Rebound Metering Rod with the flats on the Rebound Knob.
For Trunnion Eyelets: Insert the Rebound Detent Spring followed by the detent ball into the hole in the eyelet adjacent to the Rebound Knob location. Insert the red Rebound Knob into its position in the Eyelet. Insert the Rebound Metering Rod into the Eyelet through the hole for the Shaft with the o-ring end first. Engage the hex feature of the Rebound Metering Rod with the flats on the Rebound Knob.
Step 5
Clean the Shaft with Isopropyl alcohol and a lint-free paper towel. Clamp the Shaft in your shaft clamps leaving space between the Eyelet and the clamps to allow for further tightening. Tighten the Eyelet clockwise to 110 in-lb (12.4 Nm) torque with the Eyelet Torque Tool (PN: 398-00-280) or the Trunnion Eyelet Torque Tool (PN: 398-00-099).
Step 15
Install a new FOX 5wt. Teflon Infused Oil coated o-ring from the kit into the mounting hole for the Reservoir Assembly. Reinstall the Reservoir Mounting Screw tightening clockwise to 50 in-lb (5.7 Nm) with a 4mm hex wrench. Press a new white Delrin ball from the kit into the screw connecting the Reservoir Assembly to the Eyelet Assembly.
Step 19
Reinstall the Compression Cartridge Housing Assembly into the Reservoir so you can access the two screws for the Solenoid End Cap Retainer Plate with the Cable Connector facing toward the IFP Reservoir. Press it in fully to allow room for the retaining ring. Reinstall the wire retaining ring making sure it is fully seated.
Step 20
Position the Cable Connector of the Solenoid in its position above the Solenoid Retainer Plate. Orient the Cable Connector so it faces toward the IFP Reservoir. Coil the Solenoid wires carefully so you do not pinch them during Cable Connector installation. Reinstall the Solenoid End Cap Retainer Plate tightening the two set screws clockwise to 2 in-lb (0.2 Nm) torque with a 0.050" hex wrench.
Step 21
Connect the Andreani Fill Machine to the bleed port of the LIVE Valve shock using the Fill Machine Adaptor (PN: 803-00-370). Cycle the shock by hand while you perform the vacuum cycle. Then cycle the shock by hand as you perform the fill cycle. Repeat as necessary to purge all air from the shock. Set the IFP to 1.310" (33.3mm). Remove the Fill Adaptor.
Step 24
Pull up on the Rezi Endcap Assembly to seat it against the wire Retaining Ring. Thread a 5/16-24 threaded rod or bolt into the Reservoir End Cap then pull up. If you do not have a 5/16-24 threaded rod or bolt, pull up on the Reservoir End Cap with pliers on the flats of the raised portion of the end cap. Do not use pliers on the external threads of the end cap. Replace the Resi End Cap Lockring, tightening it clockwise until hand tight.
Step 26
With the Pellet Retainer just snug, fill the IFP chamber to 150psi. Tighten the pellet retainer clockwise to 14 in-lb (1.6 Nm) torque. Use the Solenoid Switcher tool (398-00-820) to dyno the shock to check all damper functions. Once happy with the dyno results, install a new white Delrin ball into the Pellet Retainer.
Step 27
Coat the main air seals on the Bearing Assembly with a film of Float Fluid. Coat the negative air seals in the end of the Air Sleeve Assembly with a film of Float Fluid. Start reinstalling the Air Sleeve onto the shock damper. Inject 2cc of Float Fluid into the main air chamber. Continue to install the Air Sleeve Assembly threading it clockwise into the Eyelet tightening until hand tight.