SERVICE PROCEDURES
2022-2025 FLOAT X Rebuild
Required Parts
- 025-03-063 Oil: Suspension Fluid, 4 WT, 1.0 Liter Bottle
- 803-01-727 Seal Kit: 2022 Float X Air Sleeve
- 803-04-008 Seal Kit: 2024 FLOAT X Rebuild
Required Tools
- 398-00-280 Tooling: Eyelet Torque Tool
- 398-00-558 Tooling: Pin Spanner Wrench
- 398-00-951 Tooling: Torque Fixture, 54mm Trunnion Eyelet, Tall
- 803-00-805 Kit: Shaft Clamps, Shocks, CTD 9mm, 3/8in, 1/2in, 5/8in
- 803-01-691 Kit: Tooling, .210-36 Vacuum Oil Fill, 2022 Shock, Andreani Thread, with O-ring
- 803-01-692 Kit: Tooling, Rear Shock, Air Fill Adaptor, MY 2022, with O-ring
WARNING: Always wear safety glasses and protective gloves during service to prevent potential injury. Failure to wear protective equipment during service may lead to SERIOUS INJURY OR DEATH.
NOTE: As many assemblies are shared between the FLOAT X and DHX shocks, some images in this rebuild procedure may show a DHX shock. Please follow all instructions in this rebuild as they are for FLOAT X shocks.
WARNING: Never attempt to pull apart, open, disassemble, or service a FOX shock that is in a “stuck down” condition. A “stuck down” condition results from a failure of the dynamic air seal, resulting with the negative chamber retaining a higher pressure than the positive chamber. To test whether the shock is in fact “stuck down”:
- Remove the air cap, connect your FOX high-pressure pump to the Schrader valve, then slowly release all air pressure from the positive chamber of the shock.
- If the shock body retracts into the air sleeve near bottom-out after the air is released from the positive chamber, attach a FOX high-pressure pump and pressurize the shock to 250 psi (17 bar).
- If the shock does not fully extend, it is in a “stuck down” condition.
- Any attempt to service FOX air shocks in the “stuck down” condition can lead to SERIOUS INJURY OR DEATH. Contact FOX or an Authorized Service Center for repair.
WARNING: FOX products should be serviced by a qualified bicycle service technician, in accordance with FOX specifications. If you have any doubt whether or not you can properly service your FOX product, then DO NOT attempt it. Improperly serviced products can fail, causing the rider to lose control resulting in SERIOUS INJURY OR DEATH.
WARNING: Modification, improper service, or use of aftermarket replacement parts with FOX forks, shocks, and seatposts may cause the product to malfunction, resulting in SERIOUS INJURY OR DEATH. DO NOT modify any part of a fork, shock, or seatpost including the fork brace (lower leg cross brace), crown, steerer, upper and lower leg tubes, or internal parts, except as instructed herein. Any unauthorized modification may void the warranty, and may cause failure or the fork or shock, resulting in SERIOUS INJURY OR DEATH.
WARNING: FOX products contain pressurized nitrogen, air, oil, or all 3. Misuse can cause property damage, SERIOUS INJURY OR DEATH. DO NOT puncture, incinerate or crush any portion of a FOX product. DO NOT attempt to disassemble any portion of a FOX product, unless expressly instructed to do so by the applicable FOX technical documentation, and then ONLY while strictly adhering to all FOX insturctions and warnings in that instance.
NOTE: Only use FLOAT X specific volume spacers in FLOAT X shocks. Usage of volume spacers intended for other products may cause internal damage that could require replacement of the eyelet assembly or other components.
NOTE: Do not overtighten the air valve core when reinstalling into the eyelet if it has been removed. Thread the air valve core in clockwise until the plunger of the air valve core is 0.010"-0.040" below the level of the Schrader valve housing.
Disassembly
WARNING: Please verify that all air has been released from the air chamber by pushing down on the Schrader valve core. Failure to release all air pressure before further disassembly may cause parts to eject causing SEVERE INJURY OR DEATH.
Step 4
Unthread the Air Fill Cap counter-clockwise with a T8 Torx driver then set it aside. Thread the MY22 Air Fill Adaptor (PN: 803-01-692) clockwise into the Reservoir End Cap fully to release the IFP pressure (if attached to a FOX high-pressure pump, use the pump to bleed out all air from the reservoir). Remove the Air Fill Adaptor by unthreading it counter-clockwise.
Step 5
Push the Reservoir End Cap into the Reservoir to gain access to the wire retaining ring. Remove the wire retaining ring by pushing the center of the ring down which will cause the ends of the ring to pop up. Be careful not to scratch the IFP bore while removing or installing this ring. Use a small hex wrench to lift the Reservoir End Cap out from the Reservoir.
Step 9
For 47.5mm-75mm travels: Remove the bearing housing cap and any travel spacers (if present) by unthreading counter-clockwise and removing the two screws with a 2mm hex wrench. Lift the bearing housing cap to expose the pin spanner holes in the bearing assembly.
Use the Pin Spanner Wrench (PN: 398-00-558) to unthread the bearing housing assembly counter-clockwise.
Step 12
Further disassembly of the base valve piston is only needed if inspecting or changing valving. If needed, temporarily reinstall the base valve piston into the reservoir making sure to align the tabs of the piston with the notches in the wall of the reservoir. Unthread the base valve bolt counter-clockwise with a 9mm socket.
Step 13
Inspect the base valve shims and replace any that are damaged or worn. Reinstall the base valve bolt into the piston taking care not to pinch any shims. temporarily reinstall the base valve piston into the reservoir making sure to align the tabs of the piston with the notches in the wall of the reservoir. Tighten the base valve bolt clockwise to 60 in-lb (6.8 Nm).
Step 16
Remove the bearing housing assembly followed by the bearing housing cap, bottom out bumper, and bottom out plate. Some shocks may use an o-ring as the bottom out bumper. In shock that use an o-ring as the bottom out bumper, a bottom out spacer is required in addition to the plate and o-ring. Remove any shaft travel spacers if present.
General Reassembly
Step 2
You do not need to remove the 2 Pos Lever, P-S No Lever, or Remote cable hangar assemblies during a standard full rebuild. The following steps show removal of the 2 Pos Lever Assembly but the procedure is the same for the P-S No Lever Assembly.
Use a T8 Torx driver to unthread the lever set screw counter-clockwise without fully removing it from the lever. Remove the lever and set it aside. Remove the two 2mm screws by unthreading them counter-clockwise.
Step 3
Remove the cam and hold down by pulling them out of the eyelet. Clean and inspect the parts, then apply a thick layer of Ultraplex LT2 or Stay Lube SL3125 Blue waterproof grease to the cam (Ultraplex LT2 blue waterproof grease shown). Note the dimple on the cam hold down and orient it toward the reservoir. Reinstall the cam and hold down then reinstall the two 2mm screws tightening clockwise to 11 in-lb (1.2 Nm) torque.
Step 5
With the rebound rod removed you may remove the red rebound knob if needed to clean and regrease the detent mechanism. Remove the rebound knob by slowly pulling it out from the eyelet taking care not to lose any of the 4 0.125" diameter balls. Remove the detent balls and springs from the rebound knob, then clean the knob.
Step 6
Coat the rebound knob in a thick layer of Ultraplex LT2 or Stay Lube SL3125 Blue waterproof grease (Ultraplex LT2 shown). Reinstall the detent springs into the holes. Reinstall the detent balls to either end of each spring. Slowly reinsert the rebound knob with detent balls and springs into the eyelet taking care to squeeze the detent balls into the eyelet as you insert the rebound knob.
Step 9
Replace the quad ring and backup rings on the bearing housing assembly. Note the original configuration (default or flipped) of the thick and thin backup rings and replace the new ones in their original configuration. Replace the o-rings within the bearing housing assembly with new greased ones from the kit. Reinstall the bearing housing assembly onto the shaft as shown. Install a new greased topout o-ring from the kit onto the shaft.
Step 13
Reinstall the rebound rod into the shaft with the ball end first. Push down on the rebound rod while you turn the red rebound knob counter-clockwise until you feel the stop. This verified that the rebound rod is fully seated in the groove of the rebound knob and that the rod won't be pinched when tightening the piston bolt later.
Step 17
Reinstall the lockout plate spring onto the adjuster shaft then reinstall the adjuster shaft with new o-rings into the reservoir making sure to engage the feature on the end of the adjuster shaft with the matching feature on the inside of the LSC knob or P-S cap. Reinstall the adjuster shaft spring.
Step 18
Reinstall the rebuilt base valve piston. Orient the tabs on the outside edge of the base valve piston to the notches in the inside wall of the reservoir. The base valve piston will not install correctly if the tabs are not aligned with the notches. Install a new greased reservoir o-ring from the kit into the reservoir while holding the base valve piston down against the springs.
Step 20
Replace the o-ring on the IFP with a new greased one from the kit. Coat the inside wall of the reservoir with a thin film of FOX 4 wt. oil. Reinstall the IFP into the reservoir. Reinstall the bleed screw with new greased o-ring from the kit into the IFP, tightening clockwise to 7in-lb (0.8 Nm) torque while holding the flats of the IFP. Reinstall the wire retaining ring into the groove in the reservoir as shown.
Step 21
Clamp the body in your soft jawed vise then reinstall the shaft assembly tightening the bearing housing clockwise to 240 in-lb (27.1 Nm) torque.
For 37.5mm-45mm travels: Use a 32mm wrench to tighten the bearing housing clockwise.
For 47.5mm-75mm travels: use the Pin Spanner Wrench (PN: 398-00-558) to tighten the bearing housing clockwise (shown).
Vacuum Bleed/Fill and Final Assembly
Step 1
Open all adjuster by turning them fully counter-clockwise. Remove the oil fill plug by turning it counter-clockwise with a T8 Torx driver. Make sure that your vacuum bleed machine is filled with FOX 4wt. oil (PN 025-03-063). Install the vacuum fitting (PN 803-01-691) into the body fill port by turning it clockwise. Cycle the shock by hand while you perform the vacuum cycle. Repeat as necessary to purge all air from the shock. Set the IFP to the appropriate depth based on the length of your reservoir.
Step 3
Remove the wire retaining ring by pushing the center of the ring down which will cause the ends of the ring to pop up. Be careful not to scratch the IFP bore while removing or installing this ring. Coat the inside of the reservoir with a thin film of FOX 4wt. oil. Replace the o-ring of the reservoir end cap with a new greased one from the kit. Reinstall the reservoir end cap into the reservoir pushing down to allow for installation of the retaining ring.
Step 4
Reinstall the wire ring. Use a small hex wrench to lift the reservoir end cap into place making sure to orient the fill port away from the damper body. Install the air fill adaptor by threading it in clockwise. Set the IFP pressure to 150 psi. Remove the air fill adaptor while still attached to your pump. Reinstall the air fill cap with a new greaswed o-ring from the kit, tightening clockwise to 3 in-lb (0.3 Nm) torque.
Step 6
Begin to reinstall the air sleeve assembly onto the shock damper. Add 2cc of FOX 20wt. gold oil into the positive air chamber. Push the air sleeve assembly to the eyelet then tighten clockwise until hand tight. Add air to your desired pressure then reinstall the black air cap. Clean the exterior of the shock then dyno test all functions.